If you have one of the recalled refrigerators you should: Only operate the refrigerator on electric until recall service has been performed. recall. your fridge! This page is to try and answer questions on the Norcold 1200 series recall. REQUIREMENTS FOR ALL PACKAGES SENT TO ARPC LLC: Before using the mailing address, Model: 637360 the low voltage for a typical RV fridge is 10.5VDC, but this is just a rule of thumb. REV-E drawing The Fridge Defend by ARP - A Small Investment Yielding Huge Returns - Your Safety! 0000018039 00000 n Automatically switches to LP operation if electricity is unavailable. To put it another way, the Norcold temperature sensor is not warm. These temperatures generally do not exceed 400F. Please click here for ARPC LLC policies on fridge manufactures' recalls. ARPC L.L.C. We are not an authorized Norcold repair facility, thus all information on this page can be considered hearsay, it is the opinion of our customers, and we cannot confirm the truth behind this information regarding the Norcold They will check for leaking ammonia and if NO obvious leaks will bypass the Recall control for 24 hours and check performance of the refer. If your fridge is not working, please start by checking your fuses and circuit breakers. Interesting that our insurance company has a lawsuit against the company as we are the second fire claim they have. all the time. ARPC LLC is not responsible for any materials published without our ARPC LLC is not responsible for shipping damage or loss. 0000001766 00000 n from our website by agreement to our terms and conditions Norcold Recall on an '07 Meridian winnieowners.com Click Here to Login: Register: Files: Registry. Please click here to see the science behind boiler temperature regulation. such as the Fridge Defend is not necessary! The 1200 and 1201 have been superseded by the 1210 and 1211. It is possible I suppose, particularly since my coach is a very early '03 model year mfg, but you might want to check to be sure!! Refrigerator model and serial numbers can be viewed by looking on the inside right of your refrigerator cabinet. Have the following materials readybefore you continueto the registration form: To identify which model refrigerator you have, look for the serial plate in one of the three locations noted below. Continued propane gas mode operation of a refrigerator under this recall could result in a fire causing injury or death. Touch device users, explore by touch or with swipe gestures. These refrigerators should be retrofitted using NORCOLD RECALL KIT - HTS supplied by Norcold. LED FLASH FAST (On/Off ~2 or 3 times per second): A Norcold service technician stated (not confirmed) that this could mean that the sensor is not connected to the recall kit. For those looking for an alternative option to the dreaded Norcold recall box that stops your refer from working every time it gets wet, this may be it. A defect inside the unit (the boilertubes). Yes, there were 3 recalls to try and address this problem. If you have a 1200 model and fall under any kind of recall, past or present, please call Norcold in order to get the appropriate model high limit/ temperature switch. the end user will follow this information at their own risk. 0000043093 00000 n Immediately switch your refrigerators controls to AC power (or DC power, if available, while in transit). If the light quits flashing you found your 621991001 RV Power Circuit Board for Norcold N611/N610/N811/N810, 621991001 Power Board Kit, Perfect Replacement for Norcold Refrigerator board PartsBelow 9056491. Restated, the Norcold temperature sensor is not hot. "high temperatures" Websites that are not authorized by ARPC LLC have plagiarize and If detected, it would cut off power to the refrigerator control boardand shut down the fridge automatically. Aside from that, continue camping and having fun. Norcold has had several recalls. ", And here we see the proof that the Fridge Defend by ARP is needed. We at Fridge Defend took the last step; we found the control parameter that protects the fluids within the cooling unit. Follow the steps below to reset your Norcold refrigerator. 3. As stated above, the recall leaves you stranded if it trips due to any other reason than a true failure What a mess. a magnet by the LED while the cover is on the kit control. be removed by compressing the clips identified in the image to the left. Nothing really new. nor in official publications by ARPC. Most likely because the cooling unit is being taxed a little harder to cool the larger volume of space. Remove the plug found between the +12VIN and +12VOUT wires put a jumper between these . The PolarMax 18 delivers value, ease-of-use, abundant storage & exceptional styling. All humor put aside, there is no Clearly, operation of the cooling unit while the they can not get into a Norcold repair facility. Some models of Norcold refrigerator have the potential to catch fire, taking your whole rig with it. If your refrigerator is part of the recall, a technician will come to your home to install a new . Legible photos of the ARP Control List of ebooks and manuels about Norcold recall kit. solution circulation has ceased, the heat, Dometic Property Damage; Fires & Explosions Patent, Dometic/Electrolux - Boiler & Fire Containment Patents, stress, which in turn prevents personal and property damage, due to fire and explosion when a system ruptures, continually strive to improve the safety and efficiency. A note must accompany the package with detailed reason for shipment along with Therefore, Fridge Defend is 2 times safer while avoiding costly fridge failure!! Skip to the end of the images gallery Just recently, the matter came to my attention once again. This is just These model refrigerators have been out of production for a long while now, however, there are still replacement boards available. ARPC LLC is not responsible for any materials published without our 3) Norcold Refrigerator Cooling Unit Temperature Monitor Control 637360 kit started its life as an NHTSA recall for the Norcold 1200, 1201, 1210 & 1211 refrigerators as a result of fire issues. This type cooling unit is original equipment on the 1200, 1201, and 1210 model. Even then, an investigator can make mistakes or jump to conclusions due to not examining and processing all the facts. "Norcolds Recall Kit 634737 does not and cannot address off-level tilting conditions.". table below has quotes on the left, and response to the quotes Click or tap the image to enlarge. Apparently, Im fine. Northcentral Oklahoma. %%EOF The universal boards we have will NOT work if the recall has not already been done on your refrigerator. 1200, 1201, 1210 and 1211, 4 door refrigerators with cooling unitserial numbers ranging from 700000 to 13085759. Legible photos of the ARP Control On March 7, 2018, Norcold announced and undertook a motor vehicle equipment safety recall (18E013) to address a potential safety defect at the propane gas valve on Norcold refrigerator model numbers N305 and N306 with serial numbers ranging from 27378283 to 28230836, non-consecutively, built from Sept. 15, 2017 to Feb. 15, 2018. Im trying to get my hands on a replacement black box that supposedly remedied the recall problem. We can tell you that the boiler needs to caused by a leak and the possibility of Anytime the Our first priority is the safety of our products and the satisfaction of our customers. If your fridge is off, the first step is to see if the red LED is turned on? requirements. Is your Norcold N611 or N811 blinking 4 times, pausing, then blinking , All prices are in USD 2023 RV Fridge Guys. Energy-efficient operation reduces battery demand. the area to apply the magnet: Norcold 1200 Series Recall. 0000001341 00000 n Running your air conditioning units to eliminate the stuffy feeling in the air can be a huge waste of electric power and money, It makes no sense to run the A/C when youve got a, One of the best things about living the RV lifestyle is the beautiful scenery youll enjoy right outside your front door. $222.99 $187.47. This means that when you operate your refrigerator on AC, the AC power supply is inverting that current to DC voltage in order to run the compressor. Blogs: FAQ: Community: Calendar: Today's Posts: Search: Log in Thread Tools: Search this Thread: Display Modes 12-16-2010, 12:12 AM #1: amanda_h. of the cooling unit which generated the refrigerant (commonly called the boiler). immediately. Turn the manual shut-off valve to OFF and operate it only on AC or DC power until the defect is repaired. A defect inside the unit (the boiler tubes). ", "If the pressurizing gas is still in place when the rupture occurs, hydrogen gas may be Other recalled refrigerators may have been purchased as a replacement during the same period. Click the link to the right to go directly to the subject matter on this page. Shipment must be authorized beforehand The second drawing shows how power gets from your RV to the Norcold refrigerator control via the Norcold 0000008193 00000 n Perhaps help out a few other people. Because some states or jurisdictions do not allow the exclusion or the limitation of liability for consequential or incidental damages, in such states or jurisdictions, our liability shall be limited to the maximum extent permitted by law. Note: The Fridge Defend keeps the boiler temperature at less than half of the Norcold recall if installed and maintained With Daves advice, youll find out what you need to do to ensure your unit is up-to-date with revised safety standards, and learn why the Norcold refrigerator recall is necessary for proper working condition while youre out on the road. We have 3 Norcold Polar N8X manuals available for free PDF download: Service Manual, Owner's Manual, Installation Manual . written permission, nor any materials not downloaded directly After logging in you can close it and return to this page. We are told if one does not have a strong magnet, the cover can 0000016944 00000 n Owner notification will begin in April of 2018. This page troubleshoots, resets and fixes Norcold HTS 634737 recall kit. xref If you are forced to park on a steep slope . when working on it. The refrigerator's model and serial number are located inside the fresh food compartment. Our dealer asked if we'd washed the RV & said dampness can cause false operation of the monitor. legal issue. Butte, MT 59701. . Warranty service is fast and efficient if we have all the information in our records. Energy Efficient. Thus, it is the responsibility of the user to know and understand Moreover, you could be personally liable to third parties for property damage or bodily injuries resulting from your failure to have your refrigerator immediately repaired. Step 1: Open the door of the refrigerator. But, in the case of the Norcold kit, remove the power to the terminal in the photo below with the red arrow marked +12V IN, this may prevent the kit from turning off the fridge We reserve the right to refuse service. the Fridge Defend by ARP versus Norcold Recall and why Norcold leaks My first reaction: Ah crap. The Fridge Defend can and will address off-level tilting conditions. Please click here to see video showing how this happens. If you have a Norcold 1210 model refrigerator, you should unplug it immediately and contact Norcold at 1-800-543-1219 for a free repair. PLEASE NOTE, the Norcold control can be reset if and only if the boiler has cooled. I spent 5,000 dollars and my RV is back at shop, weve had to cancel our vacation over this. Serial Plate location between January 1984 and April 30, 1995. Get either a test light to just check for power, or a volt meter to look at actual voltage power. control by passing it over this switch. All customer support will reference 0000019367 00000 n 0000002486 00000 n The recall involves removing 120 current from control wiring and Norcold's new harness has all 12 volt DC control in all harness wiring. 0000003330 00000 n Norcold to have your recall box replaced and have your fridge checked when you can get in for an JerArdra, from the RVForum, also posted a rather ingenious hack where he installed a smoke alarm and fire extinguisher specific to his refrigerator. cooling system experiences a leak.". All Norcold compressors, however, run on DC voltage. Would it not make more sense to address one of the known root Also, IF you have 120 current at the 2 spades on the control board that connect to the heater and it does NOT get hot, the heater is bad. Because the circuit board is exposed, water . This unused connection may have been loosened during the manufacturing testing process. email or use the Contact Us form from the upper menus to get current mailing Take out the vent cover and find a 120V fan that best fits and that you can secure and plug it in. Norcold "High Temperature Monitoring Control Kit 634737". performance of the refrigerator will deteriorate requiring a replacement of the cooling The second was to install a sensor to detect over heating and would shut off the power to the unit if over heating occurred. The interior of your RV can get very warm during late spring and summer, especially when driving on sunny days. Sooner or later youre going to want to enjoy your favorite television shows just for a change of, If you want to compare the benefits of LED and incandescent bulbs, this is the video to watch. (No gas leak can occur during AC or DC operation.). If there are NO lights on the front of the refr, then there is either bad communication to the lower board, or (more likely) NO 12V power into or out of the lower main circuit board. A remedy kit, and the labor to install it, is free to the consumer. We at ARPC L.L.C. 0000036646 00000 n nor in official publications by ARPC. This information is provided to help tracking number is required; email tracking number to us ASAP. You can reach them at 800 543 1219. This is the high temp switch for the 2118 model. by email, not phone call. And, if you havent heard, there has been quite the checkered history of recalls on many models of Norcold refrigerator. Based on this next photo, we deduce an opinion. When installed and maintained properly, the Please read the Recall Kit information below before placing an order. instructions. Legible photos of the ARP Control correctly! Please go to this webpage to read a letter from Norcold to Fridge Defend (aka ARP Control) to learn more: https://www.arprv.com/arp-versus-norcold-recall.phpPlease see this YouTube to see more from Dometic and Norcold documentation on this subject:https://youtu.be/gbYZFjqFT6gPlease subscribe to this channel for ongoing RV fridge information and troubleshooting. Recall kits Watch. {"email":"Email address invalid","url":"Website address invalid","required":"Required field missing"}, Norcold Refrigerator Recall: What You Need To Know, a really thoroughly researched post about the Norcold issue. in order to help prevent failure. This is just one of those things to look for periodically and be aware of. Troubleshooting Diagrams. . Tecma Silence Plus 2G Troubleshooting Diagram. These refrigerators were installed as original equipment in vehicle model years1997 to 2010. The best way to tell if the kit has been installed is to look at the part # of the circuit board. If so, Norcold Norcold High Temperature Sensor (HTS) Part. The 838 and 8310 were the first electronically controlled ammonia refrigerators put out by Norcold. ", Norcold does acknowledge the need for the Fridge Defend by ARP in this statement. Dave also shows you how to find your appliances cooling unit number, which is equally important to complete the Norcold refrigerator recall. Norcold NR751BB 2.7 Cu Ft DC Refrigerator 4.0 (98) $97099 FREE delivery Mar 7 - 10 Norcold NA8LX.3R Na8Lxr 8 Cf 3 Way Refer 2 Dr 3.5 (11) $2,26611 FREE delivery Mar 8 - 10 More Buying Choices $1,910.55 (4 new offers) NORCOLD INC 2-Way AC/LP 2DR Rh Rv 7' Refrigera 4.0 (17) $2,06492 FREE delivery Mar 8 - 10 email or use the Contact Us form from the upper menus to get current mailing In no case shall Norcold Parts Express, our directors, officers, employees, affiliates, agents, contractors, interns, suppliers, service providers or licensors be liable for any injury, loss, claim, or any direct, indirect, incidental, punitive, special, or consequential damages of any kind, including, without limitation lost profits, lost revenue, lost savings, loss of data, replacement costs, or any similar damages, whether based in contract, tort (including negligence), strict liability or otherwise, arising from your use of any of the service or any products procured using the service, or for any other claim related in any way to your use of the service or any product, including, but not limited to, any errors or omissions in any content, or any loss or damage of any kind incurred as a result of the use of the service or any content (or product) posted, transmitted, or otherwise made available via the service, even if advised of their possibility. Propane gas escaping next to a heat source means high risk of fire. Did a fair bit of damage but didnt total it so were not sure what our options are going to be yet. They said it was a brand new recall that had to be dealt with. If you check your unit for model and serial number and determine it is up for the Norcold refrigerator recall, you should contact Norcold immediately and take the appliance in for inspection and repair. Click here to get document outlining cooling unit checking technique. Like on the Norcold 1200, the control panel is usually between the fresh food compartment and the freezer. It is optional to remove the Norcold Recall Kit insulation. cannot tell you the cause of each fire, this job is left up to qualified investigators that can examine the facts at the scene of a fire. Our circuit boards will work in these models only if the recall kit has been installed. Serial Plate location prior to January 1984. Put the MH back in its parking space and turned on the refer. Honestly, Im not sure there is any concrete evidence that the burner is magically better, but it is definitely an option. NOTES: Doing your own kitchen plumbing might seem like. Please use the following links to get more information on the Norcold 1200 Series Recall: The Fridge Defend by ARP - A Small Investment Yielding Huge Returns - Your Safety! 1) We use the term "Default Fridge Defend Set-Point" simply because the Fridge Defend can be tuned for either a Dometic, Norcold, or Amish cooling unit fridge. Add To Cart. Got a Norcold refrigerator inside your RV? ARPC LLC is not responsible for shipping damage or loss. Norcold's 2-way interface #615281 - Pre recall board Please contact Also, failed inverter charging systems can This photo shows the kit insulation removed to aid the viewer. WITHOUT FRIDGE DEFEND YOU ARE NOT PROTECTED. the control. "catastrophic conditions" Norcold ARP Endorsement. 2020 Grand Design Solitude S-Class 3350RL. It is also a one-way shutdown, meaning that you cant turn it back on. If you are camping remote, and 3024 Wharton ~ ARPC L.L.C. But, that page wasnt timestamped so I didnt really know if it was new or not. The first was a device to prevent over heating. unit. Note: If you are going to work on the power supply to your RV, always remove power as a safety precaution. was implemented to resolve this described ", "The potential safety problem is induced by elevated heat during operation in the AC electric mode. appointment. A note must accompany the package with detailed reason for shipment along with The issue is with the cooling unit. Aqua-Magic V Hand Flush Troubleshooting Diagram. Most folks know that there are cooling unit failures that can result in fire. tracking number is required; email tracking number to us ASAP. Other times, they remove the Butte, MT 59701. 0000016642 00000 n ", "Such temperatures are only experienced at the location of the Norcold sensor if the Please click here for ARPC LLC policies on fridge manufactures' recalls. It can help you spot issues before you make the deal. 442 refrigerator pdf manual download. Yeah me, too. ), Norcold Board Kit 637779 (replaces 633292) fits N621/ N821 model, Norcold Thermistor Assembly 618548 (fits all N6/ N8/ 900/ 9000 models), Norcold Lamp Bracket Assembly 61629722/ 638292 (fits most models!). We at ARPC L.L.C. from the sealed pressurized cooling unit through a small crack which could occur from Following is the relevant contents of a letter from Norcold sent to the NHTSA This will all be explained in the next sections. The only REAL fix would be to replace the cooling unit or worse, get a new fridge. However, it is still a band-aid and does not completely mitigate the risk of fire. so mid April we start the trip going back on . In 2010, Norcold released a recall notice to all owners of a number of the companys refrigerator models in regard to an issue with the cooling unit that could lead to hazardous fire. ". If the fluids in the system are maintained at proper temperatures the result is limiting The plug found between the +12VIN and +12VOUT wires and put a jumper between these wires in order to fool Call me a half-timer. All customer support will reference If the fridge turns on, then the Norcold recall box has failed and will include Norcold's correspondence so that the facts are gleaned clearly. FREE delivery Wed, Mar 8. Any suggestions welcome . The R-0101 is not the frig control board. If you see any yellow powder substance inside the compartment around the burner, you need to get the unit looked at immediately. "ARP Control solves problems with the refrigerator whereas the Norcold control solves a If there are charges or fees associated with the return, do not reset these devices, we recommend our customers to take their Norcold fridges to Norcold authorized dealers for any re-set or work on this control. 0000044137 00000 n my 30 Dutchman with a 1998 Norcold refer was plugged in all winter. Norcold took the first 3 step to try and solve the issues that resulted in cooling unit failures. If the serial number falls in the range of, Identify and write down the cooling unit serial number. 0000017698 00000 n These tubes can corrode prematurely and this results in propane gas escaping. Doug 0000018359 00000 n The result in RV fridge fires that may have been prevented. Is your Norcold not working? Location:Anderson, Indiana. Contact a Dealer/Service Center to arrange a service date as soon as possible. Norcold 2118 fridge problem. No LP gas power operation should occur because it could create an unsafe condition. 0000054769 00000 n ARPC L.L.C. To find out if your refrigerator falls within either of the recalls, please reference the affected Dometic refrigerator model & serial numbers below. ". 400 SERIES PART # DESCRIPTION 624274 KIT-COMBINATION CONTROL WITH FITTINGS (CONTACT NORCOLD RECALL) . 0000018851 00000 n Are any of these fires on 12 volt refrigerators? All company, product and service names used on this website are for identification purposes only. nor in official publications by ARPC. The Norcold, Inc. refrigerators listed below have been recalled. WITHOUT FRIDGE DEFEND YOU ARE NOT PROTECTED. situation may occur. All content from this site is Copyright & Trademark 2015-2022, all rights reserved. A note must accompany the package with detailed reason for shipment along with Explore. The ARP typically will turn off your fridge if the boiler gets over 400 degrees F. The ARP relay is a normally closed relay, thus the relay has to be activated to turn off the refrigerator. Today. To identify if a refrigerator requires corrective action, verify the refrigerator model and the serial number as referenced above. Some potential customers and a few RV repair technicians have stated that On the other hand, the ARP measures only the boiler temperature (blue arrow) if the sensor is installed correctly. Norcold Inc. has decided to recall certain 1200, 1201, 1210 and 1211 model gas/electric refrigerators with serial numbers from 315525 to 13088811, non-consecutively. kit function. RESET: The figure to the left is a Norcold recall found on the 1200 series fridges. The blue arrow points to However, this matter can be confusing. NORCOLD is registered trademark owned by Norcold, Inc. RV Parts Express LLC is not affiliated with Norcold Inc. or Thetford Corporation. Now, all Norcold cooling units contain a temperature sensor to ensure your appliance automatically shuts off when it gets too hot. from our website by agreement to our terms and conditions If it has a part # 615282 or # 615281 the recall kit has not been installed, and our circuit boards will not work, Norcold's 2-way interface #615281 - Pre recall board, Board Kits (Optical Display Board and Main Power Board). installation need to be emailed to us that includes all wiring before removal from fridge. Posted August 4, 2012. The Norcold info is at Recall Info We not true; the proof is in the correspondence. So, I thought Id look into it myself. The recall kit (which we do not supply, but should be available from Norcold) consists of some wiring changes, a new eyebrow board and a new interface board. LED ON: If the red LED is on, some of these kits have been reset by Norcold users when Norcold 2118SS Refrigerator L1 Op Fault. 3024 Wharton ~ Please log in again. Owners were instructed to contact their RV dealer or a Norcold Authorized Service Center to arrange a service date. If there are charges or fees associated with the return, If you have one of the recalled refrigerators you should: Clickhereto see if a N305 or N306 serial number falls under this recall or check the status of a recalled unit. prevent The 1210 and 1211 are the exact same refrigerator in every way. 0000001984 00000 n The ARP control responds to conditions that can cause failure by limiting the boiler temperature to around 400 degrees F rather than allowing runaway temperatures that approach 800 degrees F. We hope this information on the Norcold control is useful, please share your experience with us. The LP light came on then switched to AC, the unit shut off, tried it many times same result. Or, the sensor continually strive to improve the safety and efficiency". Full list of return policies are found on the purchase page. Brand: Norcold . Finally, someone got it. gas absorption cooling units used on refrigerators supplied by Norcold to manufactures of high temperature kit. that the recall cannot We have determined that a defect relating to motor vehicle safety exists in some specific Yay. Contact your dealer, a Norcold Authorized Service Center or Norcolds Recall Center at. Fridge works great! The refrigerators model and serial number are located inside the fresh food compartment. Open toolbar. The majority of the recalled units are in RVs built from September 2017 to January 2018. Dometic & Norcold reliability and fire safety, can you live without it? In the event of a recall or safety notice, well be able to contact you immediately. 0000065810 00000 n Please contact Norcolds Recall Center at 1-800-444-7210 (Option 1) with any questions. This page is to troubleshoot Norcold 634737 recall kit and share reset recall information if you experience fridge off or Norcold not working. I told the service manager that I also needed the second recall done on the refer. So just tonight, a loud fan noise is coming from the bottom. Click here to see video of recall adjustment temperature, fire and explosion when a system ruptures, Click here to see video of recall and steel material softening. cover and power up and down the control, while rallying RV'ers chant, This code is triggered when the Temperature Monitor indicates that the boiler of the refrigerator is overheated. In this case, disconnect your rig from shore power and make sure your batteries are fully We are told that one must sing and dance while conditions in which liquid is drained from the system (e.g. The proposed fix was to install a high temperature sensor. 0000003171 00000 n (not confirmed) that this could mean that the sensor is not connected to the recall kit. We at Fridge Defend took the last step; we found the control parameter that protects the fluids within the cooling unit. <<6311886591BA084AAA13B4D8DF26544C>]/Prev 258899>> Let us know what you think? connection that has high resistance or charge your batteries. The Norcold kit sensor measures the temperature of the heaters (red arrows), flue tube (orange arrows), and the boiler tube (blue arrow); it appears to be for turning off the heat source only if there is a major failure that raises the temperature to over 800 degrees F. In addition the Norcold kit uses a normally open relay; there must be power to the Norcold kit to keep the relay closed at the time of this writing.